Air Conditioning & Heating Services Near Poolville, TX
Comfort Experts is proud to serve Poolville, TX, and the surrounding areas with quality, comprehensive HVAC services. Since 1962, we've helped local homeowners take their indoor comfort to the next level. Whether you need installation, replacement, maintenance or repair, we've got you covered - 24/7! We offer a wide range of services, including AC, heating, plumbing, electrical and solar energy. We're proud to offer a free second opinion so you know you're always getting a fair deal. With Comfort Experts, you'll never have to compromise on comfort. We know the ins and outs of heating, cooling and more so you don't have to.
See what your Poolville, TX, neighbors are saying about our exceptional service. We're here for you day and night, so when you need HVAC care you can trust, give us a call at 817-341-5149 !
Local Reviews
for Poolville, TX
Our Reviews by City
Mark was determined and dedicated To funding to finding our problem our problem our problem
Donna - Poolville, TX 76487
Mark is a professional who knows his work and doesn’t mind explaining what we don’t understand
PoolvilleTX76487 32.985-97.9275Clutch service!
Domingo - Poolville, TX 76487
Very helpful and knowledgeable on looking at our unit at 10pm on a Monday!!
PoolvilleTX76487 32.895-97.8825Exemplary Service
Gerald - Poolville, TX 76088
Hobson AC/Comfort Experts service exceeded my expectations and believe me with Hobson being my last name we are our biggest critics. Brian, Brady, Joe, Jose, Daniel and Jonathan all showed up and within 3 hours had the new Generac generator set, hooked up and professionally installed. I could not be any more pleased. I’m not looking forward to another electricity outage but if we have one we are a little better prepared. Thank you gentlemen on a job well done. Mr. & Mrs. Hobson Peaster, TX.
PoolvilleTX76088 32.875-97.8725Fast/Effecient
Thomjoncd - Poolville, TX 76487
Shiwed uo on time and git the jib done
PoolvilleTX76487 33.0575-97.9425Great Service
Sgt Ruben Gonzales - Poolville, TX 76487
The technician was very helpful and explained everything and told me what I needed to do the next time it happened
PoolvilleTX76487 33.04-97.85Great service!
Kevin - Poolville, TX 76487
PoolvilleTX76487 32.935-97.8775
AC Repair
Mr. H - Poolville, TX 76487
Great job guys. Think about this who needs their AC fixed on December 27th. We did. Great job.
PoolvilleTX76487 32.875-97.875Great service
Karen - Poolville, TX 76487
He was very professional and told me options that I might have to do
PoolvilleTX76487 32.9725-97.855
Response from Comfort Experts Inc.:
Thank you for taking the time to provide the awesome feedback Karen!
Great Service
Sgt Ruben - Poolville, TX 76487
The three men that came out did such a great job I was so amazed how will they did considering the conditions they were working with in such Heat I feel so bad for them but overall I couldn't have asked for a better crew
PoolvilleTX76487 33.04-97.85Very helpfull
Ricky - Poolville, TX 76487
PoolvilleTX76487 32.9625-97.815
Dennis did awesome job !
Greg - Poolville, TX 76487
PoolvilleTX76487 33.05-97.8375
fast service
Ted - Poolville, TX 76487
everyone is so nice weather its the office or worker
PoolvilleTX76487 32.9225-97.92Amazing service!!
Travis - Poolville, TX 76487
Installation was awesome! Highly recommended!!
PoolvilleTX76487 32.9775-97.8775
Response from Comfort Experts Inc.:
Thank you kindly 🙂
Great service!
Travis - Poolville, TX 76487
Great customer service!
PoolvilleTX76487 32.9775-97.8775Great Service!
Mark - Poolville, TX 76487
Mark was a pleasure during the install. Entertaining too!
PoolvilleTX76487 32.9775-97.8775
Response from Comfort Experts Inc.:
Thank you
Great service! Installation was awesome!
Mark - Poolville, TX 76487
Mark was great!! I will definitely refer all of my friends.
PoolvilleTX76487 32.9775-97.8775
Response from Comfort Experts Inc.:
Thank you for the compliment
mark.grant@acgenius.com
2022 Amana airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Evaporator coil was acceptable Blower motor and wheel were acceptable Heat strips were functional and within manufacture range Uv bulb was not functional 2022 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was heavily compacted with dust Washed condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv bulb replacement, pan treatment and Renewal of maintenance plan Installed uv bulb replacement, pan treatment and converted to HBPPLAN
Ian C.
During inspection I found that the homes insulation levels are extremely low, r value of r15 Recommended doing a r29 upgrade for more efficient home and more efficient duct work Need to follow up Amp draws acceptable Coil a little dirty Compressor acceptable Fan motor acceptable
Ian C.
Cust has two water heaters one from 1991 one from 94 they are operating but they are leaking. Showed these issues to cust they want to wait till they fail completely. I am no responsible for any issues that may arise due to water heaters
mark.grant@acgenius.com
2020 airhandler Checked and tightened all electrical connections Customer recently changed filter Drain was clear and draining poured a gallon of water down Blower motor and wheel were compacted with dust and dirt build up Evaporator coil was acceptable 2020 Bryant heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Cleared debris from bottom of unit Waxed top of unit Recommended uv light, compressor saver, blower cleaning and pan treatment
Derek.bryant@acgenius.com
Plumbing Inspection Home is in great shape
Jose M.
Install Daikin complete. Check collected 18k heat pump mini split with new lineset and cover new frame for indoor unit
Tyler L.
Tyler L has installed the new inverter it is producing power but communication to their Wi-Fi network has not been established every time I have attempted to do so it is told me not available so on the 28th I would like to have a phone call with them to see if they have any update on the established communication
Kellen M.
2013 hp. Evaporator coil - leaks detected, rust and biological growth present. Capillary tubing rubbing against door. Blower housing- fins rusty, motor has large oil spot. Electrical Heatstrips OHMS below manufacturer requirements. Critter fecal matter present inside ducting and indoor cabin. Outdoor unit‐ low Refrigerant charge. Compressor has very high RLA amps. Aux heat kicks on automatically, indicating poor performance. Wife had me speak to husband on the phone. He received all of my information about the system with no surprise. Claimed the summertime days were a struggle with system performance. Wife claims compressor noises often. After expressing the systems age, reliability and performance, and that it is not wise to put anymore money into a sinking ship; homeowner agrees to a CA appointment 12/9/23 @10am to discuss a more reliable and efficient system for the family. Technician recommendation - Superior IAQ air scrubber upon new system install to give the family clean, h
Mark W.
Called solarege they are going to send A new inverter and a customer will call me and let me know when it's here.
Kellen M.
After my evaluation, checking all incoming volts, amps, boards and capacitors I found a lose 24V R on the indoor uni that was breaking the saftey drain switch. Once I resat the wires and wire nut, power passed and the system came on. Monitored and took temperature readings. Left system in heat mode 72.
Mark D.
During inspection discovered that system was not getting adequate airflow across the coil caused by not having enough return air being drawn in and once we added more airflow sc and sh stabilized to the appropriate readings One return duct that is 18inches and two return vents that are 13.5"x13.5" Have install return to fix return air coming into the system
Dennis C.
Rescheduled comfort advisor for 11-7-23 12-3
Dennis C.
Supply plenum fell off, evaporator coil rusty and leaking, low refrigerate, compressor amping high, secondary drain pan rusty. System upgrade, comfort advisor 11-2-23 12-3.
Brock S.
Install 42K downflow indoor only with high efficiency filtration
Justin P.
On arrival customer stated they didn't have heat. Opened electrical cabin for airhandler and found very bad corrosion from water to electrical components. Connections appeared to be shorted and wires are in bad shape as well. Unit is very dirty. Unit Isn't inclosed and customer stated it hasn't had a filter in 2 years. Notified customer that the unit is unsafe. Turned breakers to unit off system is down. Talked to Rob G to send CA put for new airhandler, CA appointment at 4pm 10/17
Kellen M.
Customer ordered two Aprilaire 410 filters, replaced one and left the other. Put a comfort experts sticker on indoor unit and dated filter replacement.
Brock S.
Customer is deciding between partial home back up and whole home. I am calling back with final quote.
Kellen M.
System was in great shape except the very dirty airflow restricting filter. Please have filter sent to office and keep me informed as soon as the 2 pack 410 Aprilaire filters come in. Customers are handicapped and need our assistance.
Alec G.
During inspection discovered that refrigerant levels were low and the reading kept fluctuating told customer I would like to setup an appointment to return next weekend due to it getting late and the issue was not currently causing a problem and he said that was fine Call customer around Thursday to confirm if Friday is still good for us to return Send Mark W on return call next week
Jose G.
Install 2 heat pump downflow systems 24k and 36k keep current filtration
Jose M.
Lv 3 mini split for apartment, paying in full @ install, install pending equipment
Wyatt C.
On arrival the system was freezing up , upon further investigation found a leak in the Evaporator coil , customer has home warranty and will contact them to see if they will replace the coil. Electronic leak searched system found leak on bottom right side by the rust and corrosion base of header plate, went on the face side and found solid leak detection reccomend to replace coil and touch back with us.
Mark D.
Lennox air handler with heat pump installed in 2002. R-22 system. Arrived to no cool. Discovered 60/7.5 capacitor reading .1/7.3. Replaced capacitor and system started up and cooled to a 21 degree delta T. TXV system showing that subcooling is low at 2.1 degrees meaning that system is low on refrigerant. Customer is not interested in replacing system at this time.
Dennis C.
Condenser fan motor, compressor amping high, blower motor leaking oil, evaporator coil rusty corroded and dirty, build up on blower wheel, biological growth, system upgrade do to age condition and refrigerate phase.
Mark D.
Replaced evap coil, purged with nitrogen, pulled vacuum and recharged with 9 pounds of 410a. Need the proper sized pass through breakers. Both breakers on system are 45amp and tech was given a 30 amp and a 60 amp. Need to return with the correct breakers to finish job.